Beamline Summary
| Port | Short Name | Beamline Name | Energy Range | Techniques & Instruments | Operator |
|---|---|---|---|---|---|
| 1B | DPC |
|
|||
| 3A1 | WS-DCM |
|
7–18 keV |
|
Amitava Roy |
| 3A2 | WS-XRD |
|
7–18 keV |
|
|
| 3A3 | WS-SAXS |
|
11.9 keV |
|
Miriam Siebenbuerger |
| 4A | VLSPGM |
|
200 eV–1.2 keV |
|
Orhan Kizilkaya |
| 4B | 5-m TGM |
|
20–300 eV |
|
Orhan Kizilkaya |
| 5A1 | MPW- Biomed-Tomo |
|
35–60 keV |
|
Kyungmin Ham |
| 5A2 | MPW-PwX |
|
7–15 |
|
Amitava Roy |
| 5A3 | MPW-HEXAS |
|
4.5–25 keV |
|
Amitava Roy |
| 5B | DCM |
|
1.8–6 keV |
|
Amitava Roy |
| 6A | LEXAS |
|
1.2–1.8 keV |
|
Amitava Roy |
| 6B | EUV |
|
13.5 nm |
|
Phil Sprunger |
Vacuum UV, & Soft X-ray
Varied-Line-Space Plane Grating Monochromator Beamline (VLSPGM), Port 4A, 7 mrad
- High-resolution soft x-ray beamline, range 200 -1200 eV
- Resolving power 5000
- NEXAFS, XAS, MCD measurements
- View Upgraded varied-line-space PGM beamline at CAMD (PDF) for more details.
- Orhan Kizilkaya, orhan@lsu.edu
5-meter Toroidal Grating Monochromator Beamline (5m-TGM), Port 4B, 6 mrad
- High-resolution VUV beamline, range 25 – 240 eV
- Resolving power 800 at 200 eV
- ARUPS, LEED, Dual-anode X-ray source
- XAS measurements
- Omicron EA-125 photoelectron analyzer for ARUPS and XPS
- View High-throughput Toroidal Grating Beamline for Photoelectron Spectroscopy at CAMD (PDF) for more details.
- Orhan Kizilkaya, orhan@lsu.edu
X-ray Techniques
MPW Probe with X-rays – PwX
- Energy range 7.0 - 15 keV with resolution of 3 eV, suitable for macromolecular crystallography, XANES, XRD
- Amitava Roy, reroy@lsu.edu
- Energy range 6.0 - 60 keV with energy resolution 1-3% and spatial resolution ~3 µm
- X-ray phase contrast imaging - Talbot Laue interferometry - radiograph, phase-contrast, dark-field imaging
- Kyungmin Ham, kham1@lsu.edu
SAXS - Small Angle X-ray Scattering Beamline
- Double-crystal monochromator with energy range from ~5-11KeV
- Online 200mmx200mm multiwire gas detector
- Sample to detector distance adjustable from 0.9m to 4.9m
- View SAXS for further details.
- Miriam Siebenbuerger, msiebenbuerger@lsu.edu
X-ray Absorption Spectroscopy Beamlines
- LEXAS: Low Energy X-ray Absorption Spectroscopy
Energy range: 1.2 – 1.8 keV - DCM: Double Crystal Monochromator Beamline
Energy range: 1.8 – 6 keV - WDCM: Wavelength Shifter XAS
Energy Range: 7 – 18 keV - HEXAS: High Energy X-ray Absorption Spectroscopy
Energy range: 4.5 - 25 keV - PWX: MPW Probe with X-rays
Energy range: 6 – 14 keV - View X-ray Absorption Spectroscopy (XAS) for further details.
- Amitava Roy, reroy@lsu.edu